Yazar "Arslan, Bayram" seçeneğine göre listele
Listeleniyor 1 - 6 / 6
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Aging and cardiac implantable electronic device complications: is the procedure safe in older patients?(ELSEVIER, 2023) Güzel, Tuncay; Aktan, Adem; Kılıç, Raif; Günlü, Serhat; Arslan, Bayram; Arpa, Abdulkadir; Güzel, Hamdullah; Tatlı, İsmail; Aydın, Saadet; Suzan, Veysel; Demir, MuhammedBackground In this study, we investigated whether there is a higher incidence of cardiac implantable electronic devices (CIED) procedures related complications in older (≥75 years) than in younger (<75 years) patients. Methods This retrospective cohort study enrolled patients who had undergone CIED procedures (de novo implantation, system upgrade, generator substitution, pocket revision or lead replacement) at two heart centers in Turkey between January 2011 and May 2023. The primary composite endpoint included clinically signifcant hematoma (CSH), pericardial efusion or tamponade, pneumothorax, and infection related to the device system. Secondary outcomes included each component of the composite end point. Results The overall sample included 1923 patients (1419<75 years and 504 aged≥75 years). There was no diference between the groups in terms of cumulative events defned as primary outcome (3.5% vs. 4.4%, p=0.393). Infection related to device system was signifcantly higher in the≥75 age group (1.8% vs. 3.4%, p=0.034). There was no signifcant diference between the groups in terms of clinically signifcant hematoma and pneumothorax (0.7% vs. 0.4%, p=0.451, 1.4% vs. 1.0%, p=0.477, respectively). In multivariate model analysis, no association was found between age≥75 years and infection related to the device system. Conclusion Infection rates were relatively higher in the patient group aged≥75 years. This patient group should be evaluated more carefully in terms of infection development before and after the procedure.Öğe Aging and cardiac implantable electronic device complications: is the procedure safe in older patients?(Springer, 2023) Güzel, Tuncay; Aktan, Adem; Kılıç, Raif; Günlü, Serhat; Arslan, Bayram; Arpa, Abdulkadir; Güzel, Hamdullah; Tatlı, İsmail; Aydın, Saadet; Suzan, Veysel; Demir, MuhammedBackground: In this study, we investigated whether there is a higher incidence of cardiac implantable electronic devices (CIED) procedures related complications in older (≥ 75 years) than in younger (< 75 years) patients. Methods: This retrospective cohort study enrolled patients who had undergone CIED procedures (de novo implantation, system upgrade, generator substitution, pocket revision or lead replacement) at two heart centers in Turkey between January 2011 and May 2023. The primary composite endpoint included clinically significant hematoma (CSH), pericardial effusion or tamponade, pneumothorax, and infection related to the device system. Secondary outcomes included each component of the composite end point. Results: The overall sample included 1923 patients (1419 < 75 years and 504 aged ≥ 75 years). There was no difference between the groups in terms of cumulative events defined as primary outcome (3.5% vs. 4.4%, p = 0.393). Infection related to device system was significantly higher in the ≥ 75 age group (1.8% vs. 3.4%, p = 0.034). There was no significant difference between the groups in terms of clinically significant hematoma and pneumothorax (0.7% vs. 0.4%, p = 0.451, 1.4% vs. 1.0%, p = 0.477, respectively). In multivariate model analysis, no association was found between age ≥ 75 years and infection related to the device system. Conclusion: Infection rates were relatively higher in the patient group aged ≥ 75 years. This patient group should be evaluated more carefully in terms of infection development before and after the procedure.Öğe Comparison of Evolut-R 34 mm Valve and Smaller Evolut-R Valves in Patients Undergoing Transcatheter Aortic Valve Implantation and Determination of Mild Paravalvular Leak Predictors(Turkish Society of Cardiology, 2024) Kılıç, Raif; Güzel, Tuncay; Aktan, Adem; Demir, Muhammed; Günlü, Serhat; Arslan, Bayram; Ertaş, FarukObjective: The main purpose of this study was to evaluate and compare the in-hospital, 1-month and 1-year post-procedure outcomes of patients treated with Evolut-R 34 mm and Evolut-R 23/26/29 mm devices. Additionally, the study aimed to identify factors that could predict the occurrence of ≥ mild paravalvular leaks (PVL). Methods: Between April 2015 and May 2022, 269 consecutive patients who underwent transcatheter aortic valve implantation (TAVI) with Evolut-R 34 mm (n = 66, 24.5%) and Evolut-R 23/26/29 mm (n = 203, 75.5%) devices in a single center were retrospectively analyzed. Results: Patients in the Evolut-R 34 mm group had a lower female sex ratio (16.7% vs. 66.5%, P < .001, respectively), ejection fraction (50.7 ± 10.1% vs. 54.5 ± 9.3%, P= .016, respectively), and mean aortic gradient (7.4 ± 3.3 vs. 9.2 ± 5.0, P= .026, respectively) compared to the Evolut-R 23/26/29 mm group. The groups did not exhibit any statistically significant distinctions with regard to technical success, the need for a permanent pacemaker, occurrences of stroke, major vascular complications, PVL, major adverse cardiovascular and cerebrovascular events, or mortality. Peak velocity was confirmed as a significant predictor of ≥mild PVL in both patient groups in the receiver operating characteristic curve analysis. In logistic regression analysis; In patients with Evolut-R 34 mm valve, pre-TAVI aortic valve peak velocity (odds ratio (OR) = 23.202; P= .019) and calcium volume 800 Hounsfield Units (mm3) (OR = 1.017; P < .001) were independent predictors of ≥mild PVL. Conclusion: The Evolut-R 34 mm valve has shown comparable in-hospital results with smaller valve sizes. Pre-TAVI aortic valve peak velocity and calcium volume predicted ≥ mild PVL in Evolut-R 34 mm patients.Öğe Comparison of pain levels of traditional radial, distal radial, and transfemoral coronary catheterization(ScieLO, 2023) Kılıç, Raif; Güzel, Tuncay; Aktan, Adem; Arslan, Bayram; Aslan, Muzaffer; Günlü, Serhat; Karahan, Mehmet ZülkifOBJECTIVE: The aim of our study was to compare the traditional radial artery, distal radial artery, and transfemoral artery, which are vascular access sites for coronary angiography, in terms of pain level using the visual analog scale. METHODS: Between April 2021 and May 2022, consecutive patients from three centers were included in our study. A total of 540 patients, 180 from each of the traditional radial artery, distal radial artery , and transfemoral artery groups, were included. The visual analog scale was applied to the patients as soon as they were taken to bed. RESULTS: When the visual analog scale was compared between the groups, it was found to be significantly different (transfemoral artery: 2.7±1.6, traditional radial artery: 3.9±1.9, and distal radial artery: 4.9±2.1, respectively, p<0.001). When the patients were classified as mild, moderate, and severe based on the visual analog scale score, a significant difference was found between the groups in terms of body mass index, process time, access time, and number of punctures (p<0.001). Based on the receiver operating characteristic analysis, body mass index>29.8 kg/m2 predicted severe pain with 72.5% sensitivity and 73.2% specificity [(area under the curve: 0.770, 95%CI: 0.724–0.815, p<0.0001)]. CONCLUSION: In our study, we found that the femoral approach caused less access site pain and a high body mass index predicts severe pain.Öğe The effect of body mass index on complications in cardiac implantable electronic device surgery(WILEY, 2023) Güzel, Tuncay; Demir, Muhammed; Aktan, Adem; Kılıç, Raif; Arslan, Bayram; Günlü, Serhat; Altıntaş, Bernas; Karahan, Mehmet Zülkif; Özbek, Mehmet; Aslan, Burhan; Arpa, Abdulkadir; Coşkun, Mehmet Sait; Altunbaş, Mahsum; Tüzün, Rohat; Akgümüş, Alkame; Karadeniz, Muhammed; Aydın, Saadet; Güzel, Hamdullah; Aslan, Selen Filiz; Söner, Serdar; Taş, Ahmet; Ertaş, FarukBackground: Cardiac implantable electronic device (CIED) procedures are prone to complications. In our study, we investigated the effect of body mass index (BMI) on CIED-related complications. Methods: 1676 patients who had undergone CIED surgery (de novo implantation, system upgrade, generator change, pocket revision or lead replacement) at two heart centers in Turkey and met the study criteria were included in our study. For analysis of primary and secondary endpoints, patients were classified as non-obese (BMI < 25 kg/m2), overweight (25 ≤ BMI < 30 kg/m2), and obese (BMI ≥ 30 kg/m2). The primary endpoint was accepted as cumulative events, including the composite ofclinically significant hematoma (CSH), pericardial effusion or tamponade, pneumoth- orax, and infection related to the device system. Secondary outcomes included each component of cumulative events. Results: The rate of cumulative events, defined as primary outcome, was higher in the obese patient group, and we found a significant difference between the groups (3.0%, 4.3%, 8.9%, p = .001). CSH and pneumothorax rates were significantly higher in the obese patient group (0.3%, 0.9%, 1.9%, p = .04; 1.0%, 1.4%, 3.3%, p = .04, respectively). According to our multivariate model analysis; gender (OR:1.882, 95%CI:1.156–3.064, p = .01), hypertension (OR:4.768, 95%CI:2.470–9.204, p < .001), BMI (OR:1.069, 95%CI:1.012–1.129, p = .01) were independent predictors of cumulative events rates. Conclusions: Periprocedural complications associated with CIED (especially hematoma and pneumothorax) are more common in the group with high BMI.Öğe Evaluation of Right Ventricular Global Longitudinal Strain in COVID-19 Patients After Intensive Care Unit Discharge(2023) Günlü, Serhat; Arpa, Abdulkadir; Aktan, Adem; Güzel, Tuncay; Kılıç, Raif; Kayan, Fethullah; Işık, Mehmet Ali; Çelikten, Murat; Arslan, Bayram; Karahan, Mehmet ZülkifBackground and Aim: Using two-dimensional speckle tracking echocardiography (2D-STE), the ventricular functions of hospitalized coronavirus disease-2019 (COVID-19) patients were assessed. However, there is limited information about cardiac functions in the first year after recovery from the intensive care unit (ICU). This research aims to assess the right ventricular functions of COVID-19 patients and their changes within the first year after ICU discharge using 2D-STE. Materials and Methods: The study was conducted prospectively. The study included 68 consecutive patients and 70 control patients. Echocardiography was performed in the ICU and the first year after discharge from the hospital. Right ventricular global longitudinal strain (RVGLS) was measured using the 2D-STE method. Results: The mean age of the study group was 48.67±8.10 and 37 (54.4%) patients were males. There were no substantial differences across the groups, including age, gender, body mass index, heart rate, diabetes, dyslipidemia, and smoking (P > 0.05). A substantially significant positive correlation was detected between right ventricular dimension (RAD) (r = 0.644, P < 0.001), right ventricular diastolic dimension (RVDD) (r = 0.573, P < 0.001), ferritin (r = 0.454, P < 0.001), D-dimer (r = 0.305, P = 0.011) values and RVGLS in the in-hospital and after-discharge first-year groups. The RVGLS values of the control, in-hospital, and after-discharge first-year groups were -20.36±3.06, -16.98±3.78, and -17.58±6.45, indicating a statistically significant difference across the groups (P < 0.001). Tricuspid annular plane systolic excursion was higher in the control group (P < 0.05). Conclusion: RVGLS was found to be depressed during the in-hospital period and showed no improvement in the 1 year post discharge.