CONDENSATION ANALYSIS OF THE INSULATION OF WALLS IN MARDIN PROVINCE ACCORDING TO DIFFERENT LOCATIONS
Yükleniyor...
Tarih
2019
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
In this study, condensation and vapor diffusion caused by different
positioned insulation in the wall were analyzed for Mardin province. In the
analysis, according to the 2008 standard of TS 825, the MATLAB
calculation program was used with the Glaser graphing method and
graphical user interface (GUI). Extruded polyurethane foam was used as the
insulation material and normal unreinforced concrete was chosen as the
wall. Evaporation and condensation values were determined by creating 6
different wall models with the same insulation thickness of 20 cm and an
unreinforced concrete wall was covered with 2 cm plaster on the inside with
a 3 cm thickness on the outside. The data obtained for 2 cm and 4 cm
insulation thicknesses are presented in tables and the results are interpreted
for Mardin province. Consequently, it was seen that the worst wall structure
in terms of condensation and evaporation was obtained in the middle
insulated wall and later in the interior insulated wall structure. The
externally insulated wall did not show any condensation.
Açıklama
Anahtar Kelimeler
Condensation and vapor diffusion, Glaser graphic method, TS 825 Standard, Insulation
Kaynak
European Journal of Technique
WoS Q Değeri
Scopus Q Değeri
Cilt
9
Sayı
2
Künye
ÜNAL F (2019). CONDENSATION ANALYSIS OF THE INSULATION OF WALLS IN MARDIN PROVINCE
ACCORDING TO DIFFERENT LOCATIONS. European Journal of Technique, 9(2), 253 - 262. Doi: 10.36222/ejt.648601