CONDENSATION ANALYSIS OF THE INSULATION OF WALLS IN MARDIN PROVINCE ACCORDING TO DIFFERENT LOCATIONS

dc.authorid0000-0001-6660-9984en_US
dc.contributor.authorÜnal, Fatih
dc.date.accessioned2021-09-21T09:34:58Z
dc.date.available2021-09-21T09:34:58Z
dc.date.issued2019en_US
dc.departmentMAÜ, Meslek Yüksekokulları, Mardin Meslek Yüksekokulu, Makine ve Metal Teknolojileri Bölümüen_US
dc.description.abstractIn this study, condensation and vapor diffusion caused by different positioned insulation in the wall were analyzed for Mardin province. In the analysis, according to the 2008 standard of TS 825, the MATLAB calculation program was used with the Glaser graphing method and graphical user interface (GUI). Extruded polyurethane foam was used as the insulation material and normal unreinforced concrete was chosen as the wall. Evaporation and condensation values were determined by creating 6 different wall models with the same insulation thickness of 20 cm and an unreinforced concrete wall was covered with 2 cm plaster on the inside with a 3 cm thickness on the outside. The data obtained for 2 cm and 4 cm insulation thicknesses are presented in tables and the results are interpreted for Mardin province. Consequently, it was seen that the worst wall structure in terms of condensation and evaporation was obtained in the middle insulated wall and later in the interior insulated wall structure. The externally insulated wall did not show any condensation.en_US
dc.identifier.citationÜNAL F (2019). CONDENSATION ANALYSIS OF THE INSULATION OF WALLS IN MARDIN PROVINCE ACCORDING TO DIFFERENT LOCATIONS. European Journal of Technique, 9(2), 253 - 262. Doi: 10.36222/ejt.648601en_US
dc.identifier.doi10.36222/ejt.648601en_US
dc.identifier.endpage262en_US
dc.identifier.issn2536-5010
dc.identifier.issn2536-5134
dc.identifier.issue2en_US
dc.identifier.startpage253en_US
dc.identifier.trdizinid383552en_US
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TXpnek5UVXlNZz09/condensation-analysis-of-the-insulation-of-walls-in-em-mardin-em-province-according-to-different-locations
dc.identifier.urihttps://hdl.handle.net/20.500.12514/2855
dc.identifier.volume9en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.relation.ispartofEuropean Journal of Techniqueen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCondensation and vapor diffusion, Glaser graphic method, TS 825 Standard, Insulationen_US
dc.titleCONDENSATION ANALYSIS OF THE INSULATION OF WALLS IN MARDIN PROVINCE ACCORDING TO DIFFERENT LOCATIONSen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
f4e7c56e-1d8b-4a70-992d-bd0d77796c79.pdf
Boyut:
790.05 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Araştırma Makalesi
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: